IOLAN STS-D Terminal Servers
Serial to Ethernet
- 4 or 8 port RS232 on RJ45 Ports
- 10/100 Ethernet
- Small compact size
- Wall, desk or DIN Rail mounting
Hardware Specifications - IOLAN STS-D Terminal Servers
CPU
Processor
MPC852T, 66 Mhz, 87 MIPS
Memory
RAM
32 MB
Flash
8 MB
Interface Ports
Number of Serial Ports
IOLAN STS-D
4 or 8
IOLAN STS4-P
4
Serial Port Interface
RS232 DTE on RJ45
Sun / Solaris
Sun / Oracle ‘Solaris' Safe - no break signal
sent during power cycle causing costly server re-boots or downtime
Serial Port Speeds
50bps to 230Kbps with customizable baud rate support
Data Bits
Configurable for 5,6,7 or 8-bit protocol support
Use TruePort to transparently pass 9-bit serial data
Parity
Odd, Even, Mark, Space, None
Flow Control
Hardware, Software, Both, None
Serial Port Protection
15Kv Electrostatic Discharge Protection (ESD)
Local Console Ports
RS232 on RJ45 with DB9 adapter (provided)
Network
- 10/100Base-TX Ethernet RJ45
- Software selectable Ethernet speed 10/100/Auto
- Software selectable Half/Full/Auto duplex
Ethernet Isolation
1.5Kv Magnetic Isolation
Power
Power over Ethernet
IOLAN STS-D
N/A
IOLAN STS4-P
802.3af PoE compliant data pins (1/2, 3/6 or unused pins 4/5, 7/8) (48v DC)
Power Supply
IOLAN STS-D
120 V AC (USA), 230V AC (International) Wall Power Adaptor included
IOLAN STS4-P
N/A
Power Supply Options
Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket,
4 Port: Power IN over serial cable 9-30vDC
Nominal Input Voltage
12v DC / 24v DC on Barrel Connector
Input Voltage Range
9-30v DC on Barrel Connector
Power External Device via Serial Port
IOLAN STS-D
- 4 Port: +5v DC regulated, 1W max
- 8 Port: N/A
IOLAN STS4-P
+5v DC regulated, 1W max
Typical Power Consumption @ 12v DC (Watts)
IOLAN STS-D
- 4 Port: 2.4
- 8 Port: 3.0
IOLAN STS4-P
2.4
Indicators
LEDs
- Power/System Ready
- Network Link activity
- Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output (BTU/HR)
IOLAN STS-D
- 4 Port: 8.20
- 8 Port: 10.20
IOLAN STS4-P
8.2
MTBF (Hours)
IOLAN STS-D
- 4 Port: 391,199 Hours
- 8 Port: 339,967 Hours
IOLAN STS4-P
169,753 Hours
Calculation model based on MIL-HDBK-217-FN2 @ 30°C
Operating Temperature
0°C to 55°C (32°F to 131°F)
Storage Temperature
-40°C to 85°C, (-40°F to 185°F)
Humidity
5 to 95% (non condensing) for both storage and operation.
Case
SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating
IP30
Mounting
- Wall mount - bracket included
- DIN Rail bracket optional
Product Dimensions
Weight
IOLAN STS-D
- 4 Port: 0.35 kg (0.77 lbs)
- 8 Port: 0.55 kg (1.2 lbs)
IOLAN STS4-P
0.35 kg (0.77 lbs)
Dimensions
IOLAN STS-D
- 4 Port: 112 x 82 x 28 (mm), 4.4 x 3.2 x 1.1 (in)
- 8 Port: 112 x 156 x 28 (mm), 4.4 x 6.1 x 1.1 (in)
IOLAN STS4-P
112 x 82 x 28 (mm), 4.4 x 3.2 x 1.1 (in)
Packaging
Shipping Weight
IOLAN STS-D
- 4 Port: 0.66 kg (1.46 lbs)
- 8 Port: 1.3 kg (2.9 lbs)
IOLAN STS4-P
0.54 KG (1.2 lbs)
Shipping Dimensions
260 x 170 x 70 (mm), 10.2 x 6.7 x 2.8 (in)
Regulatory Approvals
Emissions
- CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
- ICES-003, Issue 4, February 2004 (Canada)
- CISPR 32:2015/EN 55032:2015 (Class A)
- EN55011 (CISPR11)
- EN61000-3-2 : 2010, Limits for Harmonic Current Emissions
- EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker
Immunity
- CISPR 24:2010/EN 55024:2010
- EN61000-4-2: 2009 Electrostatic Discharge
- EN61000-4-3: 2006/A2:2010: RF Electromagnetic Field Modulated
- EN61000-4-4: 2004 Fast Transients
- EN61000-4-5: 2006 Surge
- EN61000-4-6: 2009 RF Continuous Conducted
- EN61000-4-8: Power-Frequency Magnetic Field
IOLAN STS-D
EN61000-4-11: Voltage Dips and Voltage Interruptions
IOLAN STS4-P
Safety
- UL/EN/IEC 62368-1
- CAN/CSA C22.2 No. 62368-1
- IEC 60950-1 (ed 2); am1 am2 and EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013
- CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, Second Edition
Other
- Reach, RoHS and WEEE Compliant
- ECCN - 5A992
- HTSUS Number: 8517.62.0020
- Perle Lifetime Warranty
IOLAN STS-D
- 4 Port: CCATS - G168387
- 8 Port: CCATS - G168389
IOLAN STS4-P
CCATS - G168388
IOLAN RJ45 Serial Connector Pinout for STS4-D and STS4-P
Pinout
1
2
3
4
5
6
7
8
9
10
Direction
N/A
in
out
in
out
in
N/A
in
out
N/A
EIA-232
Power In (9-30V DC)
DCD
RTS
DSR
TxD
RxD
GND
CTS
DTR
Power Out
IOLAN RJ45 Serial Connector Pinout for STS8-D
Pinout
1
2
3
4
5
6
7
8
Direction
in
out
in
out
in
N/A
in
out
EIA-232
DCD
RTS
DSR
TxD
RxD
GND
CTS
DTR
Software Features - IOLAN STS-D Terminal Servers
Serial Port Access
- Connect directly using Telnet / SSH by port and IP address
- Connect with EasyPort menu by Telnet / SSH
- Use an internet browser to access with HTTP or secure HTTPS via EasyPort Web menu
- Java-free browser access to remote serial console ports via Telnet and SSH
- Ports can be assigned a specific IP address ( aliasing )
- Multisession capability enables multiple users to access ports simultaneously
- Multihost access enables multiple hosts/servers to share serial ports
Accessibility
- In-band (ethernet) and out-of-band (dial-up modem) support
- Dynamic DNS enables users to find a console server from anywhere on the Internet
- Domain name control through DHCP option 81
- IPV6 and IPV4 addressing support
Availability
Primary/Backup host functionality enables automatic connections to alternate host(s)
Security
- SSH v1 and v2
- PCI DSS Compliance: TLS v1.2, TLS v1.1, TLS v1.0, SSL v3.0, SSL v2.0
- SSL Server and SSL client mode capability
- SSL Peer authentication
- IPSec VPN : NAT Traversal, ESP authentication protocol
- SSH ciphers: AES-CTR, AES-GCM and ChaCha20-poly1305
- SSL encryption: AES-GCM, key exchange ECDH-ECDSA, HMAC SHA256, SHA384
- Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2)
- Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96
- Key exchange: RSA, EDH-RSA, EDH-DSS, ADH
- X.509 Certificate verification: RSA, DSA
- Certificate authority (CA) list
- Local database
- RADIUS Authentication, Authorization and Accounting
- TACACS+ Authentication, Authorization and Accounting
- LDAP, NIS, Kerberos Authentication
- RSA SecureID-agent or via RADIUS Authentication
- SNMP v3 Authentication and Encryption support
- IP Address filtering
- Disable unused daemons
- Active Directory via LDAP
Terminal Server
- Telnet
- SSH v1 and v2
- Rlogin
- Auto session login
- LPD, RCP printer
- MOTD - Message of the day
Serial machine to Ethernet
- Tunnel raw serial data across Ethernet - clear or encrypted
- Raw serial data over TCP/IP
- Raw serial data over UDP
- Serial data control of packetized data
- Share serial ports with multiple hosts/servers
- Virtual modem simulates a modem connection - assign IP address by AT phone number
- Virtual modem data can be sent over the Ethernet link with or without SSL encryption
- TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. For a complete list of all the latest drivers click here
- TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity
- RFC 2217 standard for transport of serial data and RS232 control signals
- Customizable or fixed serial baud rates
- Plug-ins allow customer or Perle provided plug-ins for special applications
- Software Development Kit (SDK) available
- Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101
- ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP
- Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port
Console Management
- Sun / Oracle Solaris Break Safe
- Local port buffer viewing - 256K bytes per port
- External port buffering via NFS, encrypted NFS and Syslog
- Event notification
- Clustering - central console server enables access ports across multiple console servers
- Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console
Remote Access
Dial, direct serial
PPP, PAP/CHAP, SLIP
HTTP tunneling enables firewall-safe access to remote serial devices across the internet
Automatic DNS Update
Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details
- Microsoft L2TP/IPSEC VPN client (native to Windows XP)
- Microsoft IPSEC VPN Client (native to Windows Vista)
- Cisco routers with IPSEC VPN feature set
- Perle IOLAN SDS/STS and SCS models
OA&M (Operations, Administration and Management)
- SNMP V3 - read and write, Perle MIB
- Syslog
- Perle Device Manager - Windows based utility for large scale deployments
- Configurable default configuration
- Installation Wizard
- Set a Personalized Factory Default for your IOLANs
Protocols
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP
Click on a part number for ordering information
Product Image
Product Description
Power Cord & Part No.
IOLAN STS4 D Secure Terminal Server: 4 x RJ45 connectors with RS232 interface, 10/100 Ethernet, desktop/wall mount, advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD
IOLAN STS4 P PoE Secure Device Server: 4 x RJ45 connectors with RS232 interface, 10/100 Ethernet, 802.3af Power over Ethernet (PoE) compliant, desktop/wall mount, advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD
IOLAN STS8 D Secure Terminal Server: 8 x RJ45 connector with RS232 interface, 10/100 Ethernet, desktop/wall mount, advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD
Related Accessories
Accessory Image
Accessory Description
Part No.
DBA0010 - RJ-45F to DB-25F crossover (DTE) adapter #1100220-10 for console port. View Pinout
DBA0011 - RJ-45F to DB-25M crossover (DTE) adapter #1100230-10 for console ports. View Pinout
DBA0020 - RJ-45F to DB-9F crossover (DTE) adapter #1100240-10 for console ports. View Pinout
DBA0021 - RJ-45F to DB-9M crossover (DTE) adapter #1100250-10 for console ports. View Pinout
IOLAN Starter Kit (8-wire): 1x RJ-45 to DB-25 DTE Male adapter, 1x RJ-45 to DB-25 DCE Male adapter, 1x RJ-45 to DB-25 DTE Female adapter, 1x RJ-45 to DB-9 Male DTE adapter, 1x RJ-45 to DB-9 Female DTE adapter and 1x RJ45M-RJ45F Sun/Cisco crossover adapter
DIN Rail Mounting Kit for 4 & 8 port IOLAN desktop models, all Stand-Alone Media Converters and all Stand-alone Ethernet Extenders. Two of these brackets are required for the 8 port STS8-D model.
DBA0031 8pck - 8 pack of #04030080 IOLAN-RJ45M to RJ45F Sun/Cisco crossover adapter. View Pinout
DBA0020 8pck - 8 pack of #04006970 IOLAN-RJ45F to DB9F (DTE) crossover adapter. View Pinout
DBA0021 8pck - 8 pack of #04006980 IOLAN-RJ45F to DB9M (DTE) crossover adapter. View Pinout
DBA0013 8pck - 8 pack of #04006990 IOLAN-RJ45F to DB25M Straight-thru adapter for modems. View Pinout
4 Port Terminal/Device/Console Servers - Express Replacement
4 Port Terminal/Device/Console Servers - Express Replacement French
8 Port Terminal/Device/Console Servers - Express Replacement
8 Port Terminal/Device/Console Servers - Express Replacement French