IDS-105G – Industrial Gigabit Switch
6 Port Compact DIN Rail Switch
- 5 port 10/100/1000Base-T (RJ45) with 1 Gigabit fiber ports (SC/ST)
- Hazardous Location and Industrial Control Equipment Certification
- Corrosion resistant IP30 aluminum case
- Redundant dual power input 12/24/48 VDC, 18 to 30 VAC
- Overload current and reverse polarity protection
- Industrial operating temperature support up to -40 to 75C
Perle Industrial-grade Ethernet Switches are designed for industrial automation, government, military, oil and gas, mining and outdoor applications.
The IDS-105G is a 6 port Industrial Gigabit Ethernet switch providing advanced performance enabling real-time deterministic network operation. It requires no configuration and will operate instantly as soon as you power it up.
The IDS-105G which comes in a variety of models with 5 copper ports plus 1 fiber port. All are rugged fanless switches that are hardened to provide superior reliability in 0 to 60°C, or harsh extended operating temperatures from -40 to 75°C.
Perle has been designing industrial hardware for serial ModBus and Profinet to Ethernet conversion environments for over 35 years and have used this expertise to design the toughest Ethernet switches on the market. Don’t trust your critical communications to commercial switch products. Perle Industrial Ethernet switches give you proven assurance that your system will keep running for years to come.
IDS-105G Industrial Gigabit Ethernet Switch Features
Rugged design for harsh environments |
|
Reliable operation |
|
Real-time Ethernet performance |
|
Jumbo Frames | Supports Jumbo frames up to 10 KB |
Energy Efficient Ethernet (EEE) | Energy Efficient Ethernet (EEE) as per 802.3az. This provides power savings during idle network activity. |
Hardware Specifications
Power
Dual Power Input
- 12/24/48 VDC Nominal.(9.6 to 60 VDC)
- 18 to 30 VAC
Power
4-Pin Removable Terminal Block.
Connector
Grounding screw on metal chassis
Maximum Current Consumption @24 vDC
500 mA
Maximum Power Consumption @24 vDC
12.0 Watts
Overload Current Protection
Reset-able fuse provides overload current protection
Reverse polarity protection
The positive and negative inputs can be reversed providing safe and simple power connectivity.
Access Ports
RJ45
- 5 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters (328 ft)
- Auto-negotiation
- Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
- Ethernet isolation 1500 V
Fiber port
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Fixed Fiber Port Specs
Fiber1 Type | Transmit (dBm) | Receive (dBm) | Power Budget (dB) | Wavelength (nm) | IEEE | Core Size (um) | Modal Bandwidth (MHz *Km) | Maximum Operating Distance | ||
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | Min | Max | |||||||
MMF (Duplex SC/ST) | -9.5 | -4.0 | -17.0 | -3.0 | 7.5 | 850 | 1000Base-SX | 62.5 | 160 | 220 m (722 ft) |
62.5 | 200 | 275 m (902 ft) | ||||||||
50 | 400 | 500 m (1,640 ft) | ||||||||
50 | 500 | 550 m (1,804 ft) | ||||||||
50 | 500 | 1000 m (3,281 ft) | ||||||||
MMF (Duplex SC/ST) | -6.0 | 0.0 | -17.0 | 0.0 | 11.0 | 1310 | 1000Base-LX | 62.5 | 160 | 2 km (1.2 mi) |
50 | 500 | 1 km 3,280 ft) | ||||||||
SMF (Duplex SC/ST) | -9.5 | -3.0 | -20.0 | -3.0 | 10.5 | 1310 | 1000Base-LX/LH | 9 | ** | 10 km (6.2 mi) |
SMF (Simplex SC) | -9.0 | -3.0 | -20.0 | -3.0 | 11.0 | 1310 / 1490 1490 / 1310 | 1000Base-BX-U 1000Base-BX-D | 9 | ** | 10 km (6.2 mi) |
SMF (Simplex SC) | -8.0 | -3.0 | -22.0 | -3.0 | 14.0 | 1310 / 1490 1490 / 1310 | 1000Base-BX-U 1000Base-BX-D | 9 | ** | 20 km (12.4 mi) |
SMF (Duplex SC/ST) | -2.0 | 2.0 | -23.0 | -3.0 | 21.0 | 1310 | 1000Base-EX | 9 | ** | 40 Km 24.9 mi |
SMF (Simplex SC) | -3.0 | 2.0 | -23.0 | -3.0 | 2-.0 | 1310 / 1490 1490 / 1310 | 1000Base-BX-U 1000Base-BX-D | 9 | ** | 40 Km (24.9 mi) |
SMF (Duplex SC/ST) | -2.0 | 5.0 | -23.0 | -3.0 | 21.0 | 1550 | 1000Base-ZX | 9 | ** | 70 Km (43 mi) |
SMF (Simplex SC) | -2.0 | 3.0 | -26.0 | -3.0 | 24.0 | 1510 / 1590 1590 / 1510 | 1000Base-BX-U 1000Base-BX-D | 9 | ** | 80 Km (50 mi) |
SMF (Duplex SC/ST) | 0.0 | 5.0 | -32.0 | -9.0 | 32.0 | 1550 | 1000Base-ZX | 9 | ** | 120 Km (74.6 mi) |
SMF (Simplex SC) | -3.0 | 2.0 | -34.0 | -9.0 | 31.0 | 1510 / 1590 1590 / 1510 | 1000Base-BX-U 1000Base-BX-D | 9 | ** | 120 Km (74.6 mi) |
SMF (Duplex SC/ST) | 2.0 | 5.0 | -34.0 | -9.0 | 36.0 | 1550 | 1000Base-ZX | 9 | ** | 160 Km (100 mi) |
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications
Switch Properties
Standards
- IEEE 802.3 for 10Base-T
- IEEE 802.3u for 100Base-TX and 100Base-FX
- IEEE 802.3ab for 1000Base-T
- Energy Efficient Ethernet (EEE) as per 802.3az.
- IEEE 802.3x for Flow Control
Processing Type
Store and Forward, non-blocking architecture
MAC Address Table Size
8K
Packet Buffer Memory
1 Mbit
Jumbo Frame Size
10 KB
Indicators
P1
This green LED is turned on when power is applied to the power #1 input
P2
This green LED is turned on when power is applied to the power #2 input
RJ45 Ethernet
These integrated colored LEDs indicate link, activity and speed for each port.
Fiber Link
Fiber link LED indicates Link and Data Activity
Environmental Specifications
Operating Temperature Ranges
- Standard temperature models : 0°C to 60°C (32°F to 140°F).
- Industrial extended temperature models : -40°C to 75°C (-40 F to 167°F)
Storage Temperature Range
Minimum range of -25°C to 70°C (-13°F to 158°F). -40°C to 85°C (-40°F to 185°F) for industrial extended temperature models
Operating Humidity Range
5% to 90% non-condensing
Storage Humidity Range
5% to 95% non-condensing
Operating Altitude
Up to 3,048 meters (10,000 feet)
Chassis
Aluminum with an IP30 ingress protection rating
Din Rail Mountable
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
Maximum Heat Output
41 BTU/Hr
MTBF
696,618 hours (without fiber module)
522,423 (with fixed fiber module)
489,383 hours (with 1 SFP slot)
385,036 hours (with 2 SFP slots)
MTBF Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
Product Weight and Dimensions
Weight
0.32 Kg, 0.7 lbs
Dimensions (W x H x D)
35.5 x 111 x 138 mm, 1.39 x 4.37 x 5.43 inches
Packaging
Shipping Weight
0.47 Kg, 1.04 lbs
Shipping Dimensions
170 x 260 x 70 mm, 6.69 x 10.24 x 2.76 inches
Contents Shipped
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
Standards and Certifications
Safety
- UL/EN/IEC 62368-1
- CAN/CSA C22.2 No. 62368-1
- UL 60950-1
- CSA C22.2 No. 60950-1
- IEC 60950-1:2005+A1:2009 and
- EN 60950-1:2006+A11:2009+A1:2010+A12:2011
- CE Mark
- UL508 (Industrial)
EMC Emissions
- FCC 47 Part 15 Class B
- ICES-0003
- CISPR 22:2008/EN55022:2010 (Class B)
- EN61000-6-4
EMC and Immunity
- CISPR 24:2010/EN 55024:2010
- IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 6kV, Air Discharge +/- 8kV
- IEC/EN 61000-4-3 (RS) : 80 MHz to 2.7 Ghz ; 10V/m, 800 MHz to 1000 MHz; 20V/m
- IEC/EN 61000-4-4 (EFT) : DC power line +/- 2 kV, Data Line +/- 2kV
- IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 1kV, Line/Earth +/- 2kV, Data Line line/earth +/- 1kV
- IEC/EN 61000-4-6 (CS) : 150kHz to 80 MHz; 10V
- IEC/EN 61000-4-8 : (Magnetic Field): 30A/m
- IEC/EN 61000-6-2 (General Immunity in Industrial Environments)
Industrial Safety
- UL508 (Safety standard for Industrial Control Equipment)
- CSA C22.2 No. 142
Hazardous Locations (Hazloc)
- ANSI/ISA 12.12.01, Class I Division 2 Groups A-D (formerly known as UL 1604)
- CSA C22.2 No. 213
- ATEX Class I Zone 2, EN60079-0, 15
Laser Safety
- EN 60825-1
- Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.
Environmental
Other
- ECCN: 5A991
- HTSUS Number: 8517.62.0020
- 5 year Warranty
Select a Model to obtain a Part Number – IDS-105G
Operating Temperature (Std) = 0°C to 60°C (32°F to 140°F). |
|||||||||
---|---|---|---|---|---|---|---|---|---|
Model |
Choose your Fiber Connection from the table below |
||||||||
Fiber |
Transmit |
Receive |
Power |
Wavelength |
Fiber |
Operating |
|||
Min |
Max |
Min |
Max |
||||||
IDS-105G-M2SC05 | 1 x Duplex SC | -9.5 | -4.0 | -17.0 | -3.0 | 7.5 | 850 | MMF | 550 m (1,804 ft) |
IDS-105G-M2ST05 | 1 x Duplex ST | -9.5 | -4.0 | -17.0 | -3.0 | 7.5 | 850 | MMF | 550 m (1,804 ft) |
IDS-105G-M2SC2 | 1 x Duplex SC | -6.0 | 0.0 | -17.0 | 0.0 | 11.0 | 1310 | MMF | 2 km (1.2 mi) |
IDS-105G-M2ST2 | 1 x Duplex ST | -6.0 | 0.0 | -17.0 | 0.0 | 11.0 | 1310 | MMF | 2 km (1.2 mi) |
IDS-105G-S2SC10 | 1 x Duplex SC | -9.5 | -3.0 | -20.0 | -3.0 | 10.5 | 1310 | SMF | 10 km (6.2 mi) |
IDS-105G-S2ST10 | 1 x Duplex ST | -9.5 | -3.0 | -20.0 | -3.0 | 10.5 | 1310 | SMF | 10 km (6.2 mi) |
IDS-105G-S2SC40 | 1 x Duplex SC | -2.0 | 2.0 | -23.0 | -3.0 | 21.0 | 1310 | SMF | 40 km (24.9 mi) |
IDS-105G-S2ST40 | 1 x Duplex ST | -2.0 | 2.0 | -23.0 | -3.0 | 21.0 | 1310 | SMF | 40 km (24.9 mi) |
IDS-105G-S2SC70 | 1 x Duplex SC | -2.0 | 5.0 | -23.0 | -3.0 | 21.0 | 1550 | SMF | 70 km (43 mi) |
IDS-105G-S2ST70 | 1 x Duplex ST | -2.0 | 5.0 | -23.0 | -3.0 | 21.0 | 1550 | SMF | 70 km (43 mi) |
IDS-105G-S2SC120 | 1 x Duplex SC | 0.0 | 5.0 | -32.0 | -9.0 | 32.0 | 1550 | SMF | 120 km (74.6 mi) |
IDS-105G-S2ST120 | 1 x Duplex ST | 0.0 | 5.0 | -32.0 | -9.0 | 32.0 | 1550 | SMF | 120 km (74.6 mi) |
IDS-105G-S2SC160 | 1 x Duplex SC | 2.0 | 5.0 | -34.0 | -9.0 | 36.0 | 1550 | SMF | 160 km (100 mi) |
IDS-105G-S2ST160 | 1 x Duplex ST | 2.0 | 5.0 | -34.0 | -9.0 | 36.0 | 1550 | SMF | 160 km (100 mi) |
Operating Temperature (Ind) = -40°C to 75°C (-40 F to 167°F) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model |
Choose your Fiber Connection from the table below |
|||||||||
Fiber |
Transmit |
Receive |
Power |
Wavelength |
Fiber |
Operating |
||||
Min |
Max |
Min |
Max |
|||||||
IDS-105G-M2SC05-XT | 1 x Duplex SC | -9.5 | -4.0 | -17.0 | -3.0 | 7.5 | 850 | MMF | 550 m (1,804 ft) |
|
IDS-105G-M2ST05-XT | 1 x Duplex ST | -9.5 | -4.0 | -17.0 | -3.0 | 7.5 | 850 | MMF | 550 m (1,804 ft) |
|
IDS-105G-S2SC10-XT | 1 x Duplex SC | -9.5 | -3.0 | -20.0 | -3.0 | 10.5 | 1310 | SMF | 10 km (6.2 mi) |
|
IDS-105G-S2ST10-XT | 1 x Duplex ST | -9.5 | -3.0 | -20.0 | -3.0 | 10.5 | 1310 | SMF | 10 km (6.2 mi) |
* 1db/km multimode 50/125 micron fiber cable
Single Fiber (Simplex / BiDi) Models Recommended use in pairs
Operating Temperature (Std) = 0°C to 60°C (32°F to 140°F). |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model |
Choose your Fiber Connection from the table below |
|||||||||
Fiber |
Transmit |
Receive |
Power |
Wavelength |
Fiber |
Operating |
||||
Min |
Max |
Min |
Max |
|||||||
IDS-105G-S1SC10U | 1 x Simplex SC | -9.0 | -3.0 | -20.0 | -3.0 | 11.0 | 1310 / 1490 | SMF | 10 km (6.2 mi) |
|
IDS-105G-S1SC10D | 1 x Simplex SC | -9.0 | -3.0 | -20.0 | -3.0 | 11.0 | 1490 / 1310 | SMF | 10 km (6.2 mi) |
|
IDS-105G-S1SC20U | 1 x Simplex SC | -8.0 | -3.0 | -22.0 | -3.0 | 14.0 | 1310 / 1490 | SMF | 20 km (12.4 mi) |
|
IDS-105G-S1SC20D | 1 x Simplex SC | -8.0 | -3.0 | -22.0 | -3.0 | 14.0 | 1490 / 1310 | SMF | 20 km (12.4 mi) |
|
IDS-105G-S1SC40U | 1 x Simplex SC | -3.0 | 2.0 | -23.0 | -3.0 | 20.0 | 1310 / 1490 | SMF | 40 km (24.9 mi) |
|
IDS-105G-S1SC40D | 1 x Simplex SC | -3.0 | 2.0 | -23.0 | -3.0 | 20.0 | 1490 / 1310 | SMF | 40 km (25 mi) |
|
IDS-105G-S1SC80U | 1 x Simplex SC | -2.0 | 3.0 | -26.0 | -3.0 | 24.0 | 1510 / 1590 | SMF | 80 km (50 mi) |
|
IDS-105G-S1SC80D | 1 x Simplex SC | -2.0 | 3.0 | -26.0 | -3.0 | 24.0 | 1590 / 1510 | SMF | 80 km (50 mi) |
|
IDS-105G-S1SC120U | 1 x Simplex SC | -3.0 | 2.0 | -34.0 | -9.0 | 31.0 | 1510 / 1590 | SMF | 120 km (74.6 mi) |
|
IDS-105G-S1SC120D | 1 x Simplex SC | -3.0 | 2.0 | -34.0 | -9.0 | 31.0 | 1590 / 1510 | SMF | 120 km (74.6 mi) |
Operating Temperature (Ind) = -40°C to 75°C (-40 F to 167°F) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model |
Choose your Fiber Connection from the table below |
|||||||||
Fiber |
Transmit |
Receive |
Power |
Wavelength |
Fiber |
Operating |
||||
Min |
Max |
Min |
Max |
|||||||
IDS-105G-S1SC10U-XT | 1 x Simplex SC | -9.0 | -3.0 | -20.0 | -3.0 | 11.0 | 1310 / 1490 | SMF | 10 km (6.2 mi) |
|
IDS-105G-S1SC10D-XT | 1 x Simplex SC | -9.0 | -3.0 | -20.0 | -3.0 | 11.0 | 1490 / 1310 | SMF | 10 km (6.2 mi) |
Industrial Ethernet Switch Accessories | |
---|---|
Panel Mount kit PM3 | Brackets for attaching 30 to 45 mm wide Perle IDS industrial switches inside a control panel or to a wall for wall. |
Rack Mount Kit RM4U | Bracket for mounting one or more Perle DIN Rail switches in a standard 19” rack. Occupies “4U” of vertical rack space. 275 mm (10 inches) deep |
UNO-PS/1AC/24DC/60W DIN-Rail Power Supply | UNO-PS/1AC/24DC/60W DIN-Rail Power Supply: 24 VDC, 60 Watt with universal 85 to 264 VAC, -25 to 70°C extended operating temperature. Power Supply Specifications. |
UNO-PS/1AC/24DC/150W Power Supply | UNO-PS/1AC/24DC/150W Power Supply - DIN-Rail 24 VDC , 150 Watt power supply with universal 85 to 264 VAC, -25 to 70°C extended operating temperature. Power Supply Specifications. |
Application Diagrams
IDS-105G with Standard DIN Rail
Click on image to see larger version
IDS-105G with Optional Wall/Panel Mount Brackets
Click on image to see larger version
Application Diagrams
IDS-105G Industrial Gigabit Switch Diagram
Single Mode / Single Strand (WDM) Fiber
To reduce costs, or where there are limits on available fiber, Wavelength-Division Multiplexing (WDM) technology may be utilized. WDM uses separate transmit and receive frequencies to communicate on a single fiber strand. WDM technology relies on the fact that optical fibers can carry many wavelengths of light simultaneously without interaction between each wavelength. Thus, a single fiber can carry many separate wavelength signals or channels simultaneously. WDM systems are divided into different wavelength patterns, conventional/coarse (CWDM) and dense (DWDM).
When Single Strand fiber is used, you will need an “Up” side and a “Down” side when interconnecting fiber devices.
Perle offers a wide variety of Single Fiber (“Up/Down”) Ethernet Switches and Media Converters for use with single strand of fiber.
Filter your options to find the right hardware for your application
Viewing 30 of 30 products
Click on a part number for ordering information
Product Image
Product Description
Power Cord & Part No.
IDS-105G-M2SC05 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 850nm multimode port with duplex SC connector [ 550m/1804 ft ]. 0 to 60C operating temperature.
IDS-105G-M2ST05 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 850nm multimode port with duplex ST connector [ 550m/1804 ft ]. 0 to 60C operating temperature.
IDS-105G-M2SC2 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 1310nm extended multimode port with duplex SC connector [ 2km/1.2 miles ]. 0 to 60C operating temperature.
IDS-105G-M2ST2 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 1310nm extended multimode port with duplex ST connector [ 2km/1.2 miles ]. 0 to 60C operating temperature.
IDS-105G-S2SC10 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-LX/LH, 1310nm single mode port with duplex SC connector [10 km/ 6.2 miles ]. 0 to 60C operating temperature.
IDS-105G-S2ST10 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-LX/LH, 1310nm single mode port with duplex ST connector [10 km/ 6.2 miles ]. 0 to 60C operating temperature.
IDS-105G-S2SC40 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-EX, 1310nm single mode port with duplex SC connector [40 km/ 24.9 miles ]. 0 to 60C operating temperature.
IDS-105G-S2ST40 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-EX, 1310nm single mode port with duplex ST connector [40 km/ 24.9 miles ]. 0 to 60C operating temperature.
IDS-105G-S2SC70 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex SC connector [70 km/ 43.5 miles ]. 0 to 60C operating temperature.
IDS-105G-S2ST70 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex ST connector [70 km/ 43.5 miles ]. 0 to 60C operating temperature.
IDS-105G-S2SC120 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex SC connector [120 km/ 74.6 miles ]. 0 to 60C operating temperature.
IDS-105G-S2ST120 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex ST connector [120 km/ 74.6 miles ]. 0 to 60C operating temperature.
IDS-105G-S2SC160 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex SC connector [160 km/ 100 miles ]. 0 to 60C operating temperature.
IDS-105G-S2ST160 - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-ZX, 1550nm single mode port with duplex ST connector [160 km/ 100 miles ]. 0 to 60C operating temperature.
IDS-105G-S1SC10U - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1310nm TX / 1490nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 10km/6.2 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC10D - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1490nm TX / 1310nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 10km/6.2 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC20U - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1310nm TX / 1490nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 20km/12.4 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC20D - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1490nm TX / 1310nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 20km/12.4 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC40U - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1310nm TX / 1490nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 40km/24.9 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC40D - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1490nm TX / 1310nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 40km/24.9 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC80U - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1510nm TX / 1590nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 80km/49.7 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC80D - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1590nm TX / 1510nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 80km/49.7miles ]. 0 to 60C operating temperature
IDS-105G-S1SC120U - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1510nm TX / 1590nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 120km/74.6 miles ]. 0 to 60C operating temperature
IDS-105G-S1SC120D - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1590nm TX / 1510nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 120km/74.6 miles ]. 0 to 60C operating temperature
IDS-105G-M2SC05-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 850nm multimode port with duplex SC connector [ 550m/1804 ft ].-40 to 75C industrial extended operating temperature.
IDS-105G-M2ST05-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-SX, 850nm multimode port with duplex ST connector [ 550m/1804 ft ]. -40 to 75C industrial extended operating temperature.
IDS-105G-S2SC10-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-LX/LH, 1310nm single mode port with duplex SC connector [10 km/ 6.2 miles ]. -40 to 75C industrial extended operating temperature.
IDS-105G-S2ST10-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-LX/LH, 1310nm single mode port with duplex ST connector [10 km/ 6.2 miles ]. -40 to 75C industrial extended operating temperature.
IDS-105G-S1SC10U-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1310nm TX / 1490nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 10km/6.2 miles ]. -40 to 75C industrial extended operating temperature.
IDS-105G-S1SC10D-XT - Industrial Ethernet Switch - 5 x 10/100/1000Base-T RJ-45 ports and 1 x 1000Base-BX, 1490nm TX / 1310nm RX single strand single mode port with simplex ( BIDI ) SC connector [ 10km/6.2 miles ]. -40 to 75C industrial extended operating temperature.
Related Accessories
Accessory Image
Accessory Description
Part No.
Panel Mount Kit PM3 - Brackets for wall or panel mounting 30 to 45mm wide Perle IDS Industrial Switches and IRG5140+ LTE Routers.
Rack Mount Kit RM4U - 4U Rack mount for mounting DIN Rail products to a 19 inch rack.
UNO-PS/1AC/24DC/60W DIN-Rail Power Supply: 24 VDC, 60 Watt with universal 85 to 264 VAC, -25 to 70°C extended operating temperature.
UNO-PS/1AC/24DC/150W Power Supply - DIN-Rail 24 VDC , 150 Watt power supply with universal 85 to 264 VAC, -25 to 70°C extended operating temperature