PSI-MOS-RS422/FO 850 E Serial to Fiber Converter
Connect RS422 and RS485 devices to fiber optic cable
- Extend serial data up to 2.6 miles
- Immune to EMI, RFI and transient surges
- Point-to-point or star configuration
- ST type fiber connectors
- Terminal Block for 4-wire RS422/RS485 Connections
The PSI-MOS-RS422/FO 850 E Serial to Fiber Converter transparently connects 4-wire RS422/RS485 and INTERBUS devices to fiber optic cable. By transmitting serial data over optical fiber, these serial media converters provide an economical path to extend the reach of RS422 and RS485 devices.
Long Distance Serial Data Transmission over Fiber
Using the FO 850 E Serial to Fiber Converter you can extend your serial data transmission up to 4.2km (2.6 miles). The result is that any two pieces of asynchronous serial equipment, located miles apart, can communicate at full duplex over fiber optic cable at rates up to 2 Mbps.
EMI, RFI and Transient Surge Immunity
Another advantage of the FO 850 E fiber optic transmission system is the electrically isolated connection of devices. Electromagnetic interference (EMI) is a common phenomenon in typical environments like industrial plants, warehouses and factory floors. This interference can cause corruption of data over RS422 or copper-based Ethernet links. Data transmitted over fiber optic cable however is completely immune to this type of noise, thus preventing the negative effects of voltage equalization currents and electromagnetic interference on the data cables. A Serial to Fiber Media Converter therefore enables you to inter-connect your serial devices over fiber ensuring optimal data transmission, increased availability of the system, and improved network design flexibility for point-to-point connections and star structures.
Flexible Fiber Optic Connections
The FO 850 E operates at 850 nm wavelength, using a separate LED emitter and photo-detector on ST type connectors. Almost any multimode glass fiber size can be used including 50/125 m, 62.5/125 m, and 200/230 m.
Power Budget Considerations
Calculating the power budget is critically important with planning the fiber optic link. The optical power budget is the amount of light required to transmit data successfully over distance through a fiber-optic connection. The amount of light energy available within the setup will dictate the length of the fiber optic cable run between serial media converters within the network. Optical power budgets are critical to help businesses avoid signal distortion. To learn how to calculate optical power budget read our technical note. Transmit and receive dBm can be found in the Hardware specifications.
Transmit each serial signal out over 10 fiber optic lines
Up to ten (10) Serial to Fiber Converters can be grouped together using the TBUS DIN Rail bus system for voltage and data. This allows the serial converter to operate as a star coupler, taking the serial data input signal and distributing it to all Fiber optic output ports.
High Quality Features and Support
The FO 850 E are also equipped with comprehensive diagnostic functions to increase system availability, simplify start-up and permanently monitor the optical transmission quality. The integrated optical diagnostics allow permanent monitoring of the FO paths during installation and operation. The floating switch contact is activated when the signal level on the fiber optic paths reaches a critical level. This early alarm generation enables critical system states to be detected before they result in failure. These cost and time saving features, along with free worldwide technical support, make the FO 850 E serial to fiber converter the smart choice for IT professionals.
- Supply voltage and data signals routed through via DIN rail connectors
- Connections can be plugged in using a COMBICON screw terminal block
- High-quality electrical isolation between all interfaces (INTERBUS, fiber optic ports, power supply, DIN rail connector)
- Redundant power supply possible by means of optional system power supply unit
- Approved for use in zone 2
- Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
- Integrated optical diagnostics for continuous monitoring of fiber optic paths
- Floating switch contact for leading alarm generation in relation to critical fiber optic paths
- Automatic data rate detection for all data rates up to 2 Mbps
PSI-MOS-RS485W2/FO 850 E Technical Specifications
Ambient conditions
Ambient temperature (operation)
-20°C ... 60°C
Ambient temperature (storage/transport)
-40°C ... 85°C
Permissible humidity (operation)
30 % ... 95 % (non-condensing)
Altitude
5000 m (For restrictions see manufacturer's declaration)
Degree of protection
IP20
Noise immunity
EN 61000-6-2:2005
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Type of test
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result
5g, 10-150 Hz, 2.5 h, in XYZ direction
Type of test
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result
15g, 11 ms period, half-sine shock pulse
Shock
15g in all directions in acc. with IEC 60068-2-27
Noise emission
EN 55011
Noise immunity
EN 61000-6-2:2005
Free from substances that could impair the application of coating
according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standard
CUL
Standards/regulations
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6
Vibration (operation)
In acc. with IEC 60068-2-6: 5g, 150 Hz
Conformance
CE-compliant
ATEX
- II 3 G Ex nA nC IIC T4 Gc X
- II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U)
- II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)
UL, USA/Canada
- Class I, Zone 2, AEx nc IIC T5
- Class I, zone 2, Ex nC nL IIC T5 X
- Class I, Div. 2, Groups A, B, C, D
Optical interface FO
Number of FO ports
2
Transmit capacity, minimum
- -4.6 dBm (200/230 µm)
- -17.6 dBm (50/125 µm)
- -13.6 dBm (62,5/125 µm)
Minimum receiver sensitivity
-33.2 dBm
Wavelength
850 nm
Transmission length incl. 3 dB system reserve
- 2800 m (With F-K 200/230 10 dB/km with quick mounting connector)
- 4200 m (with F-G 50/125 2.5 dB/km)
- 4800 m (with F-G 62,5/125 3.0 dB/km)
Transmission medium
- PCF fiber
- Multi-mode fiberglass
Transmission protocol
Transparent to protocol for RS-422 interface
Connection method
B-FOC (duplex ST®)
General
Transmission channels
2 (1/1) RD, TD, full duplex
Bit distortion, input
± 35 % (permitted)
Bit distortion, output
< 6.25 %
Electrical isolation
VCC // RS-422
Test voltage data interface/power supply
1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise emission
EN 55011
Net weight
190.238 g
Housing material
PA 6.6-FR
Color
green
MTBF
- 320 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
- 48 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Conformance
CE-compliant
ATEX
- II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
- II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)
- II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)
UL, USA/Canada
- Class I, Zone 2, AEx nc IIC T5
- Class I, zone 2, Ex nC nL IIC T5 X
- Class I, Div. 2, Groups A, B, C, D
Digital outputs
Output name
Relay output
Output description
Alarm output
Number of outputs
1
Maximum switching voltage
- 60 V DC
- 42 V AC
Limiting continuous current
0.46 A
Power supply
Nominal supply voltage
24 V DC (With UL approval)
Supply voltage range
18 V DC ... 30 V DC
Max. current consumption
130 mA
Typical current consumption
120 mA (24 V DC)
Connection method
COMBICON plug-in screw terminal block
Serial interface
Interface 1
RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Operating mode
Full duplex
Connection method
Pluggable screw connection
Transmission medium
Copper
Transmission length
≤ 1000 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor
- 220 Ω
- 100 Ω
- 220 Ω
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Serial transmission speed
≤ 2 Mbps
Dimensions
Width
35 mm
Height
99 mm
Depth
103 mm
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
Reach and RoHS Compliant
Approvals
- cUL Listed
- cULus Listed
- UL Listed
- ATEX
- EAC
- DNV
- cUL Recognized
- cULus Recognized
- UL Recognized
Commercial data
Packing unit
1
Weight per piece
260.0 g
Country of origin
Germany
Warranty
1 Year
Classifications
eCl@ss 4.0
27230207
eCl@ss 4.1
27230207
eCl@ss 5.0
27230207
eCl@ss 5.1
27230207
eCl@ss 6.0
27230207
eCl@ss 7.0
27230207
eCl@ss 8.0
19179290
eCl@ss 9.0
19179290
ETIM 2.0
EC001423
ETIM 3.0
EC001423
ETIM 4.0
EC001423
ETIM 5.0
EC000310
ETIM 6.0
EC000310
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
43222604
Application Diagrams
PSI-MOS-RS422/FO 850 E Serial to Fiber Media Converter Applications
- near heavy electrical equipment
- in environments with electrical (EMI) or radio (RFI) interference
- in environments with transient surges
- in industrial plants, warehouses and factory floors
- enabling asynchronous serial equipment to communicate at full duplex, with rates up to 2 Mbps, over optical fiber
Point-to-point connections between serial devices over fiber
Star Topology Network
INTERBUS Networks
Click on a part number for ordering information
Product Image
Product Description
Power Cord & Part No.
PSI-MOS-RS422/FO 850 E - RS422/485 4-wire to fiber converter. Terminal block serial to duplex fiber multimode 850nm ( ST ) [ 4.2km, 2.6 miles ] - power supply optional
PSI-MOS-RS422/FO 850 E - RS422/485 4-wire to fiber converter. Terminal block serial to duplex fiber multimode 850nm ( ST ) [ 4.2km, 2.6 miles ] – 24VDC USA wall power adapter included
PSI-MOS-RS422/FO 850 E - RS422/485 4-wire to fiber converter. Terminal block serial to duplex fiber multimode 850nm ( ST ) [ 4.2km, 2.6 miles ] – 24VDC UK wall power adapter included
PSI-MOS-RS422/FO 850 E - RS422/485 4-wire to fiber converter. Terminal block serial to duplex fiber multimode 850nm ( ST ) [ 4.2km, 2.6 miles ] – 24VDC EU wall power adapter included
Related Accessories
Accessory Image
Accessory Description
Part No.
AC US WALL MOUNT ADAPT TL 24VDC , 18W wall power adapter, with tinned leads - 0 to 60C. For use with TC EXTENDER, PSI-MOS Converters, PSM-ME Isolator, PSM-ME Converter and PSM-ME Repeater
AC UK WALL MOUNT ADAPT TL 24VDC , 18W wall power adapter with tinned leads - 0 to 60C. For use with TC EXTENDER, PSI-MOS Converters, PSM-ME Isolator, PSM-ME Converter and PSM-ME Repeater
AC EU WALL MOUNT ADAPT TL 24VDC, 18W wall power adapter with tinned leads - 0 to 60C. For use with TC EXTENDER, PSI-MOS Converters, PSM-ME Isolator, PSM-ME Converter and PSM-ME Repeater
Transmit power voltage and data across the bus. Gold-plated contacts with 5 parallel positions. UL 8A / cUL 6A, 150 V. Width 17.5cm. Carton of 10. For use with PSI-MOS Serial to Fiber Converters and PSI-MODEM-SHDSL/SERIAL Copper Extenders.
Transmit power voltage across the bus. Gold-plated contacts with 2 parallel positions. UL 8A / cUL 6A, 150 V. Width 17.5cm. Carton of 10. For use with PSI-MOS Serial to Fiber Converters and PSI-MODEM-SHDSL/SERIAL Copper Extenders.
UNO-PS/1AC/24DC/60W DIN-Rail Power Supply: 24 VDC, 60 Watt with universal 85 to 264 VAC, -25 to 70°C extended operating temperature.
UNO-PS/1AC/24DC/150W Power Supply - DIN-Rail 24 VDC , 150 Watt power supply with universal 85 to 264 VAC, -25 to 70°C extended operating temperature