TRIO-PS-2G/3AC – 3 Phase DIN Rail Power Supply
Switching Power Supplies for Regulated AC to DC Conversion
- 24V DC Output Voltage
- Output Amps: 5, 10, 20, or 40 Amps
- Output Watts: 120, 240, 480, or 960 W
- 2-phase or 3-phase AC Input Voltage Range: 400 to 500 V AC
The TRIO 3-Phase Power Supplies offer a complete range of rugged AC to DC Converters built to meet the high stability and efficiency expectations of industrial, machine automation and process control environments. These Switch Mode Power Supplies ensure a regulated output voltage even in the event of voltage fluctuations in the power supply network. With all required safety certifications to support ITE (Information Technology Equipment), ruggedized packaging, extended operating temperatures, high peak load capabilities and high isolation voltages, TRIO 3-Phase Power Supplies are designed to meet the needs of your high power industrial application.
150% Dynamic Power Boost
The dynamic boost provides additional power for starting difficult loads. By supplying up to 150% of the nominal current for 5 seconds TRIO power supplies start difficult loads reliably.
24 to 28 V DC Adjustable Output Voltage Range
Using the rotary potentiometer on the front face of the TRIO power supply, the output voltage can be optimally adjusted to meet specific application environment requirements. For example, you can easily adjust to compensate for a voltage drop caused by a long cable length.
Industrial operating temperature of -25°C to +70°C
Equipment found in traffic management, oil and gas pipelines, weather tracking, industrial and outdoor applications must function in temperatures that cannot be supported by a commercial power supplies. With an operating temperature of -25°C to +70°C, the TRIO 3-Phase Power Supply is ideal for use with equipment subjected to harsh environments and severe temperatures. Some models even guarantee reliable device start-up at -40°C.
High efficiency and low no load power consumption
Compared with other products on the market, the TRIO 3-Phase Power Supply provides excellent energy savings. With a very low no load power consumption and over high efficiency at nominal load, just a small amount of electrical energy is converted into undesired heat energy making these very ECO friendly power supplies.
Easy & efficient installation
The tool-free Push-in connection will save time and make installation quick and easy. And, the DIN Rail mount narrow housing will save space in the control cabinet.
Ideal application environments for a TRIO DIN Rail Power Supply
- drive motors and other devices
- machine building
- automated production process
- industrial control, automation, assembly, and test equipment
- building control, security and surveillance, and climate control systems.
- power countless industrial automation devices such as sensors, controllers and valves
Other reasons to choose a TRIO Industrial Power Supply
- Contact signal output and LED indicator for voltage out failure: If the output voltage is below the operational range, the LED turns off and the contact opens.
- Vibration resistance up to 4 kg
- Shock resistance up to 30g
- Voltage Isolation input/output: 3 kV AC
- Protections: Short-circuit, Overload, Over voltage, Over-temperature
- High MTBF (Mean Time Between Failure) values of more than 1 million hours at +40°C ensure maximum availability
Environmental Product Compliance
REACH SVHC
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
Lead 7439-92-1
TRIO-PS-2G/3AC/24DC/40 - 29031568
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 25;
General
Net weight
TRIO-PS-2G/3AC/24DC/5 - 29031538
0.4 kg
TRIO-PS-2G/3AC/24DC/10 - 29031548
0.9 kg
TRIO-PS-2G/3AC/24DC/20 - 29031558
1.5 kg
TRIO-PS-2G/3AC/24DC/40 - 29031568
2.6 kg
Efficiency
TRIO-PS-2G/3AC/24DC/5 - 29031538
> 91 % (at 400 V AC and nominal values)
TRIO-PS-2G/3AC/24DC/10 - 29031548
> 92 % (at 400 V AC and nominal values)
TRIO-PS-2G/3AC/24DC/20 - 29031558
> 93 % (400 V AC)
TRIO-PS-2G/3AC/24DC/40 - 29031568
typ. 93 % (400 V AC)
Insulation voltage input/output
- 3 kV AC (type test)
- 1.5 kV AC (routine test)
Protection class
TRIO-PS-2G/3AC/24DC/5 - 29031538
II (in closed control cabinet)
TRIO-PS-2G/3AC/24DC/10 - 29031548
I (in closed control cabinet)
TRIO-PS-2G/3AC/24DC/20 - 29031558
I (in closed control cabinet)
TRIO-PS-2G/3AC/24DC/40 - 29031568
I (in closed control cabinet)
Degree of protection
IP20
MTBF (IEC 61709, SN 29500)
TRIO-PS-2G/3AC/24DC/5 - 29031538
> 2300000 h (25°C)
> 1300000 h (40°C)
> 620000 h (60°C)
TRIO-PS-2G/3AC/24DC/10 - 29031548
> 2100000 h (25°C)
> 1200000 h (40°C)
> 590000 h (60°C)
TRIO-PS-2G/3AC/24DC/20 - 29031558
> 1800000 h (25°C)
> 1100000 h (40°C)
> 510000 h (60°C)
TRIO-PS-2G/3AC/24DC/40 - 29031568
> 1730000 h (25°C)
> 1051000 h (40°C)
> 510000 h (60°C)
Mounting position
horizontal DIN rail NS 35, EN 60715
Assembly instructions
alignable: horizontally 0 mm (≤ 40°C) 10 mm (≤ 70°C), vertically 50 mm
Efficiency
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
500 V AC
TRIO-PS-2G/3AC/24DC/40 - 29031568
typ. 93.3 % (480 V AC)
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise emission
EN 55011 (EN 55022)
Noise immunity
TRIO-PS-2G/3AC/24DC/5 - 29031538
Immunity according to EN 61000-6-2 (industrial)
TRIO-PS-2G/3AC/24DC/10 - 29031548
Immunity according to EN 61000-6-2 (industrial)
TRIO-PS-2G/3AC/24DC/20 - 29031558
Immunity according to EN 61000-6-2 (industrial)
TRIO-PS-2G/3AC/24DC/40 - 29031568
Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
Standards/regulations
EN 61000-4-2
Contact discharge
4 kV (Test Level 2)
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
1.4 GHz ... 2 GHz
Test field strength
3 V/m (Test Level 2)
Standards/regulations
EN 61000-4-4
Comments
Criterion B
Standards/regulations
- EN 61000-6-3
- EN 61000-4-6
Frequency range
0.15 MHz ... 80 MHz
Voltage
10 V (Test Level 3)
Conducted noise emission
EN 55016 EN 61000-6-4 (Class A)
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformers
TRIO-PS-2G/3AC/24DC/5 - 29031538
EN 61558-2-16 (air clearances and creepage distances only)
TRIO-PS-2G/3AC/24DC/10 - 29031548
EN 61558-2-16 (air clearances and creepage distances only)
TRIO-PS-2G/3AC/24DC/20 - 29031558
EN 61558-2-16 (air clearances and creepage distances only)
TRIO-PS-2G/3AC/24DC/40 - 29031568
Standard - Electrical safety
IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard – Limitation of mains harmonic currents
EN 61000-3-2
UL approvals
- UL Listed UL 508
- UL/C-UL Recognized UL 60950-1
Shock
TRIO-PS-2G/3AC/24DC/5 - 29031538
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
TRIO-PS-2G/3AC/24DC/10 - 29031548
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
TRIO-PS-2G/3AC/24DC/20 - 29031558
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
TRIO-PS-2G/3AC/24DC/40 - 29031568
11 ms, 15g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
TRIO-PS-2G/3AC/24DC/5 - 29031538
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min.
TRIO-PS-2G/3AC/24DC/10 - 29031548
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min.
TRIO-PS-2G/3AC/24DC/20 - 29031558
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min.
TRIO-PS-2G/3AC/24DC/40 - 29031568
DNV GL CG-0339 / Class B 2 Hz - 100 Hz resonance search, 90 min. in resonance, 2 Hz - 13.2 Hz, ±1 mm amplitude, 13.2 Hz - 100 Hz, 0.7g acceleration
Rail applications
EN 50121-4
Shipbuilding approval
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
GL applied for
TRIO-PS-2G/3AC/24DC/40 - 29031568
Standards/regulations
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
TRIO-PS-2G/3AC/24DC/40 - 29031568
EN 61000-4-11
Overvoltage category (EN 60950-1)
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
TRIO-PS-2G/3AC/24DC/40 - 29031568
II
Overvoltage category (EN 61010-1)
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
TRIO-PS-2G/3AC/24DC/40 - 29031568
III
Connection data, input
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
10 mm
Output data
Nominal output voltage
24 V DC ±1 %
Setting range of the output voltage (USet)
24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)
TRIO-PS-2G/3AC/24DC/5 - 29031538
5 A
TRIO-PS-2G/3AC/24DC/10 - 29031548
10 A
TRIO-PS-2G/3AC/24DC/20 - 29031558
20 A
TRIO-PS-2G/3AC/24DC/40 - 29031568
40 A
Dynamic Boost (IDyn.Boost)
TRIO-PS-2G/3AC/24DC/5 - 29031538
7.5 A (5 s)
TRIO-PS-2G/3AC/24DC/10 - 29031548
15 A (5 s)
TRIO-PS-2G/3AC/24DC/20 - 29031558
30 A (5 s)
TRIO-PS-2G/3AC/24DC/40 - 29031568
60 A (5 s)
Derating
60°C ... 70°C (2.5%/K)
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
Yes
Protection against surge voltage on the output
≤ 30 V DC
Control deviation
- < 1 % (change in load, static 10 % ... 90 %)
- < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- < 0.1 % (change in input voltage ±10 %)
Residual ripple
TRIO-PS-2G/3AC/24DC/5 - 29031538
≤ 20 mVPP
TRIO-PS-2G/3AC/24DC/10 - 29031548
≤ 20 mVPP
TRIO-PS-2G/3AC/24DC/20 - 29031558
≤ 20 mVPP
TRIO-PS-2G/3AC/24DC/40 - 29031568
≤ 50 mVPP
Output power
TRIO-PS-2G/3AC/24DC/5 - 29031538
120 W
TRIO-PS-2G/3AC/24DC/10 - 29031548
240 W
TRIO-PS-2G/3AC/24DC/20 - 29031558
480 W
TRIO-PS-2G/3AC/24DC/40 - 29031568
960 W
Typical response time
< 1 s
Maximum power dissipation in no-load condition
TRIO-PS-2G/3AC/24DC/5 - 29031538
< 1 W (400 V AC)
TRIO-PS-2G/3AC/24DC/10 - 29031548
< 1.1 W (400 V AC)
TRIO-PS-2G/3AC/24DC/20 - 29031558
< 1.2 W (400 V AC)
TRIO-PS-2G/3AC/24DC/40 - 29031568
< 14 W (400 V AC)
Power loss nominal load max.
TRIO-PS-2G/3AC/24DC/5 - 29031538
< 12 W (480 V AC)
TRIO-PS-2G/3AC/24DC/10 - 29031548
< 22 W (480 V AC)
TRIO-PS-2G/3AC/24DC/20 - 29031558
< 38 W (480 V AC)
TRIO-PS-2G/3AC/24DC/40 - 29031568
< 68 W (480 V AC)
Feedback resistance
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
TRIO-PS-2G/3AC/24DC/40 - 29031568
< 35 V
Short-circuit current
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
TRIO-PS-2G/3AC/24DC/20 - 29031558
TRIO-PS-2G/3AC/24DC/40 - 29031568
< (Permanent)
Connection data for signaling
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
1.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Stripping length
8 mm
Dimensions
Width
TRIO-PS-2G/3AC/24DC/5 - 29031538
35 mm
TRIO-PS-2G/3AC/24DC/10 - 29031548
42 mm
TRIO-PS-2G/3AC/24DC/20 - 29031558
65 mm
TRIO-PS-2G/3AC/24DC/40 - 29031568
110 mm
Height
130 mm
Depth
TRIO-PS-2G/3AC/24DC/5 - 29031538
115 mm
TRIO-PS-2G/3AC/24DC/10 - 29031548
160 mm
TRIO-PS-2G/3AC/24DC/20 - 29031558
160 mm
TRIO-PS-2G/3AC/24DC/40 - 29031568
160 mm
Weight per piece
TRIO-PS-2G/3AC/24DC/5 - 29031538
568.5 GRM
TRIO-PS-2G/3AC/24DC/10 - 29031548
1070.0 GRM
TRIO-PS-2G/3AC/24DC/20 - 29031558
1717.0 GRM
TRIO-PS-2G/3AC/24DC/40 - 29031568
2850.0 GRM
Input data
Nominal input voltage range
TRIO-PS-2G/3AC/24DC/5 - 29031538
- 3x 400 V AC ... 500 V AC
- 2x 400 V AC ... 500 V AC
TRIO-PS-2G/3AC/24DC/10 - 29031548
- 3x 400 V AC ... 500 V AC
- 2x 400 V AC ... 500 V AC
TRIO-PS-2G/3AC/24DC/20 - 29031558
- 3x 400 V AC ... 500 V AC
- 2x 400 V AC ... 500 V AC
TRIO-PS-2G/3AC/24DC/40 - 29031568
- 3x 400 V AC ... 500 V AC
Input voltage range
TRIO-PS-2G/3AC/24DC/5 - 29031538
- 3x 400 V AC ... 500 V AC -20 % ....+15 %
- 2x 400 V AC ... 500 V AC -10 % ... +15 %
TRIO-PS-2G/3AC/24DC/10 - 29031548
- 3x 400 V AC ... 500 V AC -20 % ....+15 %/li>
- 2x 400 V AC ... 500 V AC -10 % ... +15 %
TRIO-PS-2G/3AC/24DC/20 - 29031558
- 3x 400 V AC ... 500 V AC -20 % ....+15 %
- 2x 400 V AC ... 500 V AC -10 % ... +15 %
TRIO-PS-2G/3AC/24DC/40 - 29031568
- 3x 400 V AC ... 500 V AC -20 % ....+15 %
AC frequency range
50 Hz ... 60 Hz
Discharge current to PE
TRIO-PS-2G/3AC/24DC/5 - 29031538
< 0.25 mA
TRIO-PS-2G/3AC/24DC/10 - 29031548
< 3.5 mA
TRIO-PS-2G/3AC/24DC/20 - 29031558
< 3.5 mA
TRIO-PS-2G/3AC/24DC/40 - 29031568
< 3.5 mA
Current consumption
TRIO-PS-2G/3AC/24DC/5 - 29031538
- 3x 0.4 A (400 V AC)
- 3x 0.3 A (500 V AC)
- 2x 0.6 A (400 V AC)
- 2x 0.5 A (500 V AC)
TRIO-PS-2G/3AC/24DC/10 - 29031548
- 3x 0.6 A (400 V AC)
- 3x 0.6 A (500 V AC)
- 2x 1.1 A (400 V AC)
- 2x 1.1 A (500 V AC)
TRIO-PS-2G/3AC/24DC/20 - 29031558
- 3x 1.2 A (400 V AC)
- 3x 1 A (500 V AC)
- 2x 2.3 A (400 V AC)
- 2x 1.9 A (500 V AC)
TRIO-PS-2G/3AC/24DC/40 - 29031568
- 3x 1.9 A (400 V AC)
- 3x 1.9 A (400 V AC)
Nominal power consumption
TRIO-PS-2G/3AC/24DC/5 - 29031538
243.6 VA
TRIO-PS-2G/3AC/24DC/10 - 29031548
451.7 VA
TRIO-PS-2G/3AC/24DC/20 - 29031558
822.2 VA
TRIO-PS-2G/3AC/24DC/40 - 29031568
1335.1 VA
Inrush surge current
TRIO-PS-2G/3AC/24DC/5 - 29031538
≤ 22 A (typical)
TRIO-PS-2G/3AC/24DC/10 - 29031548
≤ 26 A (typical)
TRIO-PS-2G/3AC/24DC/20 - 29031558
≤ 22 A (typical)
TRIO-PS-2G/3AC/24DC/40 - 29031568
≤ (typical)
Mains buffering
TRIO-PS-2G/3AC/24DC/5 - 29031538
- typ. 20 ms (400 V AC)
- typ. 20 ms (500 V AC)
TRIO-PS-2G/3AC/24DC/10 - 29031548
- typ. 10 ms (400 V AC)
- typ. 20 ms (500 V AC)
TRIO-PS-2G/3AC/24DC/20 - 29031558
- typ. 10 ms (400 V AC)
- typ. 20 ms (500 V AC)
TRIO-PS-2G/3AC/24DC/40 - 29031568
- typ. 10 ms (400 V AC)
- typ. 20 ms (500 V AC)
Input fuse
TRIO-PS-2G/3AC/24DC/5 - 29031538
3.15 A (internal (device protection), slow-blow)
TRIO-PS-2G/3AC/24DC/10 - 29031548
3.15 A (internal (device protection), slow-blow)
TRIO-PS-2G/3AC/24DC/20 - 29031558
3.15 A (internal (device protection), slow-blow)
TRIO-PS-2G/3AC/24DC/40 - 29031568
6.3 A (internal (device protection))
Choice of suitable circuit breakers
TRIO-PS-2G/3AC/24DC/5 - 29031538
6 A ... 16 A (Characteristics B, C, D, K)
TRIO-PS-2G/3AC/24DC/10 - 29031548
6 A ... 16 A (Characteristics B, C, D, K)
TRIO-PS-2G/3AC/24DC/20 - 29031558
6 A ... 16 A (Characteristics B, C, D, K)
TRIO-PS-2G/3AC/24DC/40 - 29031568
10 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi)
TRIO-PS-2G/3AC/24DC/5 - 29031538
0.55
TRIO-PS-2G/3AC/24DC/10 - 29031548
0.58
TRIO-PS-2G/3AC/24DC/20 - 29031558
0.63
TRIO-PS-2G/3AC/24DC/40 - 29031568
0.77
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Connection data, onput
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
TRIO-PS-2G/3AC/24DC/5 - 29031538
4 mm²
TRIO-PS-2G/3AC/24DC/10 - 29031548
4 mm²
TRIO-PS-2G/3AC/24DC/20 - 29031558
10 mm²
TRIO-PS-2G/3AC/24DC/40 - 29031568
16 mm²
Conductor cross section flexible min.
TRIO-PS-2G/3AC/24DC/5 - 29031538
0.2 mm²
TRIO-PS-2G/3AC/24DC/10 - 29031548
0.2 mm²
TRIO-PS-2G/3AC/24DC/20 - 29031558
0.2 mm²²
TRIO-PS-2G/3AC/24DC/40 - 29031568
0.75 mm²
Conductor cross section flexible max.
TRIO-PS-2G/3AC/24DC/5 - 29031538
2.5 mm²
TRIO-PS-2G/3AC/24DC/10 - 29031548
2.5 mm²
TRIO-PS-2G/3AC/24DC/20 - 29031558
6 mm²
TRIO-PS-2G/3AC/24DC/40 - 29031568
10 mm²
Conductor cross section AWG min.
TRIO-PS-2G/3AC/24DC/5 - 29031538
24
TRIO-PS-2G/3AC/24DC/10 - 29031548
24
TRIO-PS-2G/3AC/24DC/20 - 29031558
24
TRIO-PS-2G/3AC/24DC/40 - 29031568
20
Conductor cross section AWG max.
TRIO-PS-2G/3AC/24DC/5 - 29031538
12
TRIO-PS-2G/3AC/24DC/10 - 29031548
12
TRIO-PS-2G/3AC/24DC/40 - 29031568
8
TRIO-PS-2G/3AC/24DC/20 - 29031558
4
Stripping length
TRIO-PS-2G/3AC/24DC/5 - 29031538
10 mm
TRIO-PS-2G/3AC/24DC/10 - 29031548
10 mm
TRIO-PS-2G/3AC/24DC/20 - 29031558
15 mm
TRIO-PS-2G/3AC/24DC/40 - 29031568
18 mm
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
25°C ... 70°C (> 60°C Derating: 2.5 %/K)
Ambient temperature (storage/transport)
-40°C ... 85°C
Max. permissible relative humidity (operation)
≤ 95 % (at 25°C, non-condensing)
Climatic class
3K3 (in acc. with EN 60721)
Degree of pollution
2
Installation height
TRIO-PS-2G/3AC/24DC/5 - 29031538
≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
TRIO-PS-2G/3AC/24DC/10 - 29031548
≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
TRIO-PS-2G/3AC/24DC/20 - 29031558
≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
TRIO-PS-2G/3AC/24DC/40 - 29031568
≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Ambient temperature (start-up type tested)
TRIO-PS-2G/3AC/24DC/5 - 29031538
TRIO-PS-2G/3AC/24DC/10 - 29031548
-40°C
TRIO-PS-2G/3AC/24DC/20 - 29031558
-40°C
TRIO-PS-2G/3AC/24DC/40 - 29031568
-40°C
Approvals
- DNV GL
- cULus Listed
- cULus Recognized
- EAC
- UL Recognized
- cUL Recognized
- cUL Listed
- IECEE CB Scheme
- UL Listed
Application Diagrams
TRIO 3-Phase Power Supplies Industrial Power Supply Block Diagram
TRIO 3-Phase Power Supplies Industrial Power Supply Block Diagram
Click on a part number for ordering information
Product Image
Product Description
Power Cord & Part No.
TRIO-PS-2G/3AC/24DC/5 Power Supply - TRIO power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/5 A
TRIO-PS-2G/3AC/24DC/10 Power Supply - TRIO power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/10 A
TRIO-PS-2G/3AC/24DC/20 Power Supply - TRIO power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/20 A
TRIO-PS-2G/3AC/24DC/40 Power Supply - TRIO supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A